Magnetic Force (N) | Response time (ms) | ||||
Duty cycle ED% | Power 20°C (W) | Stroke start | End of stroke | Attraction T | Repulsion T |
100 | 3 | 0,3 | 4,9 | 30 | 31 |
40 | 7,5 | 0,5 | 7,9 | 28 | 26 |
25 | 12 | 0,8 | 9,8 | 26 | 25 |
15 | 20 | 1 | 12,2 | 26 | 25 |
5 | 60 | 2,5 | 16,5 | 25 | 25 |
Standard: Terminals | Optional: Cables | Magnetic Force (N) | Response time (ms) | ||
Duty cycle ED% | Power 20°C (W) | Stroke start | End of stroke | Attraction T | Repulsion T |
100 | 6 | 1,3 | 1,8 | 47 | 35 |
40 | 14 | 2,3 | 2,9 | 39 | 31 |
25 | 24 | 3,1 | 3,8 | 39 | 31 |
15 | 35 | 4,1 | 5 | 36 | 29 |
5 | 100 | 6,2 | 7,4 | 36 | 29 |
Standard: Terminals | Optional: Cables | Magnetic Force (N) | Response time (ms) | ||
Duty cycle ED% | Power 20°C (W) | Stroke start | End of stroke | Attraction T | Repulsion T |
100 | 7,5 | 2,5 | 7 | 50 | 34 |
40 | 17 | 5,4 | 17 | 40 | 28 |
25 | 25 | 7,5 | 21 | 37 | 26 |
15 | 38 | 10 | 24 | 37 | 26 |
5 | 95 | 17 | 32 | 35 | 25 |
Standard: Terminals | Optional: Cables | Magnetic Force (N) | Response time (ms) | ||
Duty cycle ED% | Power 20°C (W) | Stroke start | End of stroke | Attraction T | Repulsion T |
100 | 8 | 2,9 | 7,7 | 64 | 41 |
40 | 20 | 5,6 | 12 | 51 | 33 |
25 | 30 | 7,8 | 13,8 | 49 | 32 |
15 | 50 | 11,4 | 21,5 | 46 | 30 |
5 | 120 | 19,7 | 35 | 46 | 30 |
Standard: Terminals | Optional: Cables | Magnetic Force (N) | Response time (ms) | ||
Duty cycle ED% | Power 20°C (W) | Stroke start | End of stroke | Attraction T | Repulsion T |
100 | 12 | 0,1 | 60 | 127 | 59 |
40 | 30 | 6,3 | 110 | 75 | 45 |
25 | 48 | 10,6 | 160 | 72 | 44 |
15 | 80 | 14,4 | 190 | 70 | 42 |
5 | 240 | 35 | 230 | 70 | 42 |
Standard: Terminals | Optional: Cables | Magnetic Force (N) | Response time (ms) | ||
Duty cycle ED% | Power 20°C (W) | Stroke start | End of stroke | Attraction T | Repulsion T |
100 | 12 | 3,3 | 9,3 | 111 | 68 |
40 | 30 | 7,3 | 20,8 | 87 | 54 |
25 | 48 | 10 | 31,9 | 83 | 53 |
15 | 80 | 15,5 | 45,3 | 81 | 51 |
5 | 240 | 27 | 71,3 | 81 | 51 |
Standard: Terminals | Optional: Cables | Magnetic Force (N) | Response time (ms) | ||
Duty cycle ED% | Power 20°C (W) | Stroke start | End of stroke | Attraction T | Repulsion T |
100 | 18 | 9,2 | 27 | 196 | 126 |
40 | 45 | 16,7 | 60 | 143 | 95 |
25 | 70 | 21,5 | 87 | 135 | 90 |
15 | 110 | 28,5 | 103 | 120 | 81 |
5 | 280 | 50 | 150 | 117 | 80 |